Numbers of installed units:
DTL: 12
CCL: 24
SRF: 64 (assumes that all cryomodules are installed - not true as of Jan/01)
HEBT: 55
Ring: 87
RTBT: 43
Minimum requirements:
Operating modes: Commissioning;
Studies, troubleshooting;
Operational (nominal).
Beam current amplitude: 15 to 60 mA Chopped and unchopped (Linac).
Beam current width: Sub-µsec (partial mini-pulse) to 1 msec macro-pulse.
Macro-pulse chopped at ring revolution rate of ~1.07 MHz. Mini-pulse width ~
695 nsec.
Pulse repetition rate: 1 - 60 pps
Electronics Bandwidth: DC - 50 kHz.
Electronics Gain: Programmable by channel, ____ levels during macro-pulse
Upper end loss limit: Linear response for 0.5 % beam fast loss at single point
Lower end loss limit: 10% resolution of 1 W/m loss at 1 Hz bandwidth
Pulse Identification: Date/time stamp sufficient to specify macro-pulse.
Timing: Timing settable within macro-pulse with sub µsec precision.
Update rate: 1 Hz - Long-term, low level loss (each detector)
1 Hz - Standard losses (each detector, total loss all macro-pulses)
6 Hz - Detailed losses (10 detectors total, 100 µsec resolution)
Beam Inhibit Capabilities:
Fast Loss: 10 µsec Detect-to-Beam Inhibit time
Programmable threshold, each detector, ___ level changes/macro-pulse
Each detector maskable (eliminate bad channels, permit studies resulting in
higher than normal losses)
Single output line/analog crate
Long-term, low level loss: "Soft" alarm through network or
Programmable threshold, each detector,
Each detector maskable (eliminate bad channels, permit studies resulting in
higher than normal losses)
Single output line/analog crate
Local Data Storage: "Flight-Recorder Mode, 60 (1-second) records of "Detailed Losses" for each detector. Available for readback on beam abort.
In-Situ System check: On-line check of all detectors, connections and electronics
by cycling HV Off/On.
Identification: Each BLM detector and each electronics module will have a unique
serial number. A bar code shall be assigned and applied by ORNL.
Calibration: Each BLM detector and electronics channel shall have a measured and archived calibration .
Packaging: No electronics in the tunnel.
Minimum of 4 channels per analog module.
Maximum of 32 channels per analog crate.
Data acquisition uses VME environment
High Voltage: On/Off (CMD and RBAC)
Voltage level (CMD and RBAC)
Current readback
Polarity readback
0-3000 V, 1 mA
Dual HV supplies biasing alternate detectors
HV Cabling: Red RG-59 with SHV connectors (non-PTFE), (connected in daisy-chain).
Signal Cabling: Non-tribo-electric cabling with BNC connectors (non-PTFE)